View | Data

See Also:

Time, Adjusted Time, Drawdown, and Head

 

This selection displays data entered about the slug test including aquifer parameters and site information. Units are specified from Options | Units.

Following are descriptions of some data items:

Time -- The actual time value entered into Super Slug

Adjusted Time -- The time value adjusted so that a head ratio of 1.0 occurs at time = 0.0;

Drawdown -- The actual water level value entered into Super Slug. This could be measured relative to the top of the casing, the bottom of the well, the pre-test water level, sea level, or any other fixed datum. Values may be positive or negative.

Head -- The difference of drawdown and static water level. This value will be positive unless the water level oscillated past static water level during the test.

Head Ratio -- This is the ratio of Head to Initial Head. Initial head is the head at time = 0.0. Super Slug determines initial head to be the maximum deviation from static water level during a test. The user may make a different head value the initial head through adjustments in the data.